Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T11EL01757

Parcel: 130171870


Addresses:

4141 E 29TH ST #68


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T11EL01757

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/30/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
1) COMPLETE KITCHEN CABINETS AND SINK PRIOR TO OCCUPANCY
06/29/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXPOSED ROMEX AT LIGHT FIXTURE PANTRY UNDER 7" REQUIRES PROTECTION FROM PHSYICAL DAMAGE
2) EXPOSED ROMEX KITCHEN CONNECTS