Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T11EL01740
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/11/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
07/06/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL UNUSED OPENINGS IN DEADFRONT (TAPE NOT OK) 2) NOTE 3 FROM PREVIOUS-EXHAUST FAN WIRING NOT TO CODE 3) NOTE 4 FROM PREVIOUS-ALL SMOKE ALARMS MUST BE IN WORKING CONDITIONS 4) NEXT DENIAL MAY RESULT IN REFEE |
|
06/28/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING DEADFRONT AT PANEL 2) MIXED BREAKER TYPE IN PANEL 3) WIRING IN STORAGE ROOM IN GARAGE NOT TO CODE. SECURE ROMEX TO CODE. WIRING UNDER 7' MUST BE PROTECTED FROM PHYSICAL DAMAGE 4) RELOCATE SMOKE ALARMS MINIMUM 36" FROM FORCED AIR REGISTERS 6"-12" FROM CEILING |