Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/26/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 05/10/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PROPER CONNECTORS AT NEW SUB PANEL GARAGE. SEAL UNUSED OPENINGS 2) SECURE ADDED GAS LINE PER CODE GARAGE 8' ON CENTER 3) HAZARDOUS CONNECTION AT GARAGE ROOF FAN NOT TO CODE; SPLICES NOT IN APPROVED BOX. SECURE ROMEX 8" FROM BOXES 4) SEAL UNUSED OPENINGS BOTTOM MAIN PANEL 5) SEAL UNUSED OPENINGS DEAD FRONT (TAPE NOT OK) 6) NOTE: REAR PORCH NOT BUILD TO CVODE. IMPROPER CONNECTION AT FASCIA. HEADER 4 X 4 OVER SPANNED |
|
| 04/18/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |