Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/13/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 03/31/2011 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADDED 30 AMP CIRCUIT, PROVIDE SEALED CONNECTION AT SERVICE. SECURE CONDUIT PER CODE. BREAKER TYPE MUST MATCH PANEL TYPE . SEAL KNOCKOUT BOTTOM PANEL 2) PROVIDE PROOF OF PERMIT ALL ADDITIONS ATTACHED TO REAR. REAR PORCH NOT TO CODE LEDGER ON STUCCO 3) HAZARDOUS ELECTRICAL EXPOSED 22O WIRING LAUNDRY 4) MISSING HARD WIRED SMOKE ALARMS BEDROOMS 5) HAZARDOUS ELECTRICAL REAR LAUNDRY ADDITION. SPLICED CIRCUITS. CONSULT QUALIFIED ELECTRICIAN FOR WALL WORK NOT TO CODE 6) EXPOSED WIRING SMALL STORAGE ADDITION |