Permit: T11EL00705

Parcel: 134242210


Addresses:

1117 S FORDHAM DR

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/30/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/29/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEPERATE GROUNDS FROM NEUTRALS AT SUB PANEL
2) STRAP CONDUCTORS FOR REAR PORCH FLOURSCENTS
03/15/2011 ELECTRIC - FINAL Cancelled IVRS - RI canceled
03/11/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MIXED RECEPTS (2) & (3) PRONG THRU-OUT BLDG
2) NEED GFCI PROTECTION ON (3) PRONG OR REPLACE BACK TO (2) PRONG
2) ILLEGAL WIRING AT MAIN NEEDS TO BE CORRECTED
3) OVERHEAD CONDUCTORS LAYING ON TOP OF ROOF STRUCTURE AND PORCH WITH A METAL ROOF ?
4) NEED SMOKE DETECTOR IN ALL SLEEPING ROOMS
5) NEED GFCI PROTECTION ON ALL KITCHEN COUNTER RECEPTS-NO RECEPTS IN BATHROOM
6) NEED DRYER RECEPT WIRED TO CODE AND SAFE
7) NEED GFCI PROTECTION ON ALL EXTERIOR REPAIRS AT GRADE WITH BUBBLE COVERS
8) HOUSE NEEDS TO BE SAFE TO RELEASE POWER