Permit: T11EL00612

Parcel: 137281090


Addresses:

805 W WEDWICK ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/18/2012 ELECTRIC - FINAL Approved IVRS - Inspection :*
04/17/2012 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/22/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FURNACE FLEX MAY NOT PENETRATE CABINET MUST BE HARD PIPED THRU PENETRATION
2) EXTEND TPR LINE TO EXTERIOR 6"-24" FROM GROUND
3) COVER PLATES MISSING THROUGHOUT-MISSING OUTLETS
4) SECURE 220 STOVE PER CODE
5) HAZARDOUS WIRING AT STOVE EXHAUST FAN
6) SMOKE ALARM BEDROOMS AND HALLWAY
7) OMIT DBL KEYED DEAD BOLTS EXIT DOOR
8) SECURE PANEL TO WALL PER CODE
9) SEAL KNOCKOUTS BOTTOM PANEL
10) SHARED NEUTRAL WIRES BUSS ONE PER SCREW
11) PROVIDE PROOF OF PERMIT REAR PORCH WITH ELECTRICAL ON WEST PROPERTY LINE. HEADER OVERSPANNED
12) MISSING LIGHT FIXTURES EXPOSED WIRING
03/16/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST HOUSE NUMBERS
2) PROVIDE ACCESS TO STORAGE AND MECH ROOMS AT CARPORT
3) KEY IN LOCK BOX DOES NOT OPEN FRONT DOOR DEAD BOLT
4) NEXT DENIAL MAY RESULT IN REFEE
03/04/2011 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) POST UNIT NUMBERS VISIBLE FROM STREET
2) PROVIDE ACCESS TO STORAGE AND MECH ROOMS
3) GFCI PROTECT EXTERIOR OUTLETS CARPORT
4) KEY IN KEY BOX DOES NOT OPEN DOOR, DEADBOLT ONLY SECURITY DOOR