Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2011 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 02/23/2011 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PROOF OF PERMIT ALL PORCHES, NOT BUILT TO CODE. OVERSPANNED RAFTERS 2 X 6 SPAN 11'-24" ON CENTER. 4 X 4 HEADERS SPANS 11', DAMAGED RAFTERS 2) NO WATER SUPPLY TO WATER HEATER EXTEND TPR VALVE 6-24" FROM GROUND 3) PROVIDE PROOF OF PERMIT LAUNDRY ADDED. PLUMBING NOT TO CODE, WITH ADDED 220 TO DRYER. WHITE HOT LEAD MUST BE RED OR BLACK (TAPE OK) 4) LABEL CIRCUITS MAIN PANEL. SEAL KNOCKOUTS 5) HAZARDOUS ELCTRICAL AT REAR PORCH 6) PROOF OF PERMIT REAR PORCH. WHAT IS LEDGER ATTACHEMENT ? 7) GFCI PROTECT KITCHEN OUTLET AT COUNTER TOP 8) EXPOSED ROMEX KITCHEN EXHAUST FAN 9) EXPOSED ROMEX THROUGHOUT AT SWITCHES AND LIGHT FIXTURES 10) SMOKE ALARM BEDROOM AND HALLWAY 11) REAR BEDROOM WINDOWS DO NOT NEET EGRESS REQUIREMENTS |