Permit: T11EL00132

Parcel: 14025016A


Addresses:

1341 E MILTON RD

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/29/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/09/2011 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) GFCI PROTECT GARAGE OUTLETS. SEAL DEAD FRONT KNOCKOUT
2) TPR LINE TO EXTERIOR
3) BEDROOM WINDOWS LIKE FOR LIKE-NO STRUCTUAL CHANGE
4) 1992 SITE PLAN SHOWS ADDITION ON RECORD 4/3/92
01/14/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PROOF OF PERMIT CARPORT ENCLOSURE WITH BATH. LAUNDRY ROOM AND REAR PORCH ATTACHED TO REAR NOT TO CODE WITH ELECTRICAL. HEADERS OVER SPANNED. MISSING POST AT HEADER CONNECTIONS. LAUNDRY ROOM LACKS COMBUSTION RELIEF. ADDED PLUMBING 10/3 NOT TO CODE
2) GFCI PROTECT EXTERIOR OUTLETS
3) PROVIDE ACCESS REAR GARAGE ADDITION
4) SMOKE ALARM BEDROOMS
5) CHANGED WINDOW IN BEDROOM DOES NOT MEET EGRESS REQUIREMENTS. MINIMUM 20" X 30" OPENING
6) GFCI PROTECT KITCHEN COUNTER OUTLETS
7) NEW A/C UNIT OVER FUSED-PROVIDE PROOF OF PERMIT