Inspection History: ELECTRIC - FINAL
Permit Number - T11EL00073
Inspection Description - ELECTRIC - FINAL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/24/2011 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) SECURE ALL #4 WIRE TO BLDG |
|
01/21/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTE 8 FROM PREVIOUS 2) NEW PANEL NOT GROUNDED 3) PROVIDE WATER BOND 4) MIXED BREAKERS IN PANEL 5) PROVIDE CUTTER HAMMER BREAKERS |
|
01/19/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PROOF CARPORT TO GARAGE PERMIT 2) PROTECT ROMEX UNDER 7' IN STORAGE ROOM 3) MISSING COVER PLATES THROUGHOUT 4) FURNACE MUST BE OPERABLE 5) EXPOSED ROMEX KITCHEN 6) GLOBE BATH LIGHT FIXTURE 7) PROVIDE PERMIT FOR PANEL CHANGE OUT 8) WINDOW BARS NOT TO CODE |