Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2011 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 01/05/2011 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HANG FIXTURES OR COVER EXPOSED WIRES AT EXTERIOR 2) COVER PLATES NEEDED ON SWITCHES AND OUTLETS THROUGHOUT 3) RANGE CONDUCTOR CONNECTED OR TERMINATED TO CODE 4) CEILING FIXTURES HUNG OR TERMINATERD AND COVER PLATED TO CODE 5) GFI PROTECT OUTLETS IN BATHROOMS 6) FIXTURES OR COVER PLATE WALL FIXTURES IN HALLWAY 7) SMOKE DETECTORS NEEDED IN BEDROOMS AND ADJACENT HALL INSTALLED PER MANUFACTURES SPECS 8) WIRE PROPERLY PROTECTED IN CONDUCTOR AT CORNER OF HOUSE AT BACK PATIO 9) DBL UP CONDUCTORS TO 20 AMP BREAKER NOT ALLOWED IN SUB PANEL 10) RED CONDUCTOR TO GROUND BAR AT SUB PANEL NOT ALLOWED 11) PROPERLY SPLICE WIRES AT MAIN PANEL |