Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date |
Description |
Inspector |
Results |
Comments |
| 12/16/2011 |
INSP - INITIAL CODE ENFORCMENT |
|
Approved |
MET WITH THE TENANT AND IS STATING THAT THERE IS NO HEATING SYSTEM IN THE HOUSE AND IS USING PORTABLE HEATERS AND ARE PLUGGED INTO THE OUTLETS. HE HAS 6-PORTABLE HEATER AT DIFFERENT LOCATION AND THE BREAKERS ARE POPPING AT THE MAIN ELECTRICAL EXTERIOR PANEL FOR THE HOUSE. THE PANEL IS MISSING THE DEAD FRONT AND HAS DOUBLE LUGGING ON SOME BREAKERS. THERE IS A WIRE THAT IS CONNECTED TO A PINNED BREAKER FOR 220 AND IS SPLICED WITH BEING BURIED IN THE GROUND CLOSE TO THE SURFACE AND NOT RATED FOR BURIAL TYPE WIRING. THERE IS ROMEX THAT HAS BEEN ADDED TO THE MAIN SERVICE PANEL AND IS ON THE EXTERIOR OF THE HOUSE FOR EXTERIOR LIGHTING AND NOT PROTECTED PROPERLY AND SPLICED AT THE LIGHTING AND NOT IN A JUNCTION BOX. THERE IS OTHER WIRING IN PLASTIC CONDUIT ON THE EXTERIOR OF THE HOUSE AND GOES INTO THE ATTIC AND NOT ABLE TO SEE WHERE IT GOES. THERE IS A ELECTRICAL WATER HEATER ON THE EXTERIOR OF THE HOUSE AND THE WIRING IS NOT CONNECTED TO A DISCONNECT OR IN THE WATER HEATER AND SPLICED OUTSIDE THE WATER HEATER. THE T.P.R. VALVE HAS NO DRAIN LINE AND IS DIRECTED TO THE MASONRY WALL IN THE METAL ENCLOSURE. WILL TRY TO CALL THE OWNER TO CHECK ON THE STATUS OF THE HEATER FOR THE HOUSE BEING CONNECTED AND WILL CHECK WITH SUPERVISION ON IF NOT HEAT FOR THE HOUSE IS GOING TO BE INSTALLED WILL CHECK ON THE BREAKERS BEING CHECKED DUE TO POPPING. WILL DO N.O.V. RV. |