Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/21/2011 | INSP - INITIAL CODE ENFORCMENT | Approved | VIOLATIONS PRESENT Site inspection, found structure in process of being occupied. Contact attempted, no one home. Carport attached to main structure measuring approx. 12'x 18' was built by using 2"x 4" lumber & are over spanned. One edge drains onto eastside neighbors. Back porch measures approx. 12'x 30' is nailed to fascia board, lacks approved ledger to structure. Porch structure in violations of required set backs. |