Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T11DV09442

Parcel: 132110290


Addresses:

2204 E 36TH ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
11/17/2011 INSP - INITIAL CODE ENFORCMENT Approved VIOLATIONS PRESENT
Visited site, made contact w/onsite contractor & crew, crew in process of remodeling, T11PL01862 for replace gas line issued but does not cover no going work such as Hot water heater has been replace, lacks T.R.P. drain valve, gas heating appliance being replaced, new exterior copper water lines installed, along w/3 prong receptacles lacking ground. Kitchen 3 prong receptacle have no G.F.I.C. protection, Main disconnect lacking several breaker blank covers, front porch has been removed & rebuilt, lacks approved attaching hardware, improper use of materials such as section of pressure treated 4"x 4" beam toe nailed together & lacks metal flashing along exterior block wall. Due to work being done requires permit & research shows none issued, stop work order posted. NOV to follow