Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T11DV07494
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2011 | INSP - INITIAL CODE ENFORCMENT | Approved | MET WITH THE TENANT AND THE ROOF IS LEAKING ON THE SOUTHEAST CORNER OF THE UNIT IN THE LIVINGROOM. THE DRYWALL IS LOOSE AND HAS BUBBLES INCLUDING THE MASONRY WALL IN THAT CORNER. THE PAINT IS LOOSE AND PEELING. THE CARPET IS LOOSE AND OFF THE TACK STRIPS WHERE THEY ARE DRY ROTTED. THE BEDROOM HAS A LEAK IN THE CEILING BY THE CLOSET. I DID CHECK THE NEXT DOOR UNIT WHICH IS #6 AND ALSO HAS ROOF LEAKS. I DID GO ON THE ROOF AND CHECK THE COATING WHICH IS LACKING IN AREAS AND WORN. WHERE THE SCUPPER IS LOCATED IS WHERE THE UNIT HAS THE WATER COMMING FROM IN THE CEILING. BY THE FRONT AREA HAS CRACKING IN THE CANT STRIP ALONG THE PARAPET MASONRY WALL. THE ROOF HAS PONDING OF WATER IN THOSE AREA INCLUDING A PARAPET FACADE THAT WAS BUILT ON TOP OF THE EXISTING ROOF. THE PARAPET IS LACKING THE CRICKETS AND ALSO HAS WATER PONDING ALONG THE BACK SIDE OF THE WALL WHERE THE CRICKETS ARE LACKING. WILL LOOK FOR A PERMIT FOR THE WALL ADDED ON THE ROOF. WALL HAS STUCCO AND APPEARS TO BE WOOD FRAME. FACADE SPANS ON UNIT #6 & #8 AND FACES THE STREET. WILL DO N.O.V. |