Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T11DV06827

Parcel: 10513009A


Addresses:

4040 N 6TH AV

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/26/2011 INSP - INITIAL CODE ENFORCMENT Approved WENT TO RESIDENT W/INSPECTOR JH. MET W/OWNER ASKED IF WE MAY CK PROPERTY FOR COMPLIANCE AND ALSO CK ELECTRICAL SERVICE. OWNER STATED SHE HAD A CONTRACTOR CK THE OUTLET FOR COMPLIANCE SHE STATED HER ELECTRICAL WAS TO CODE. OWNER GAVE US AUTHORIZATION TO ENTER PROPERTY AND CK SITE INCLUDING ELECTRICAL. FOUND DOUBLE LUGGING AT ONLY ELECTRICAL DROP DISCONNECT. PROPERTY HAS A LOT OF IMMINENT HAZARDS: 2 - 14 GAUGE WIRES ON A 20 AMP FUSE, ROMAX NOT RATED FOR UNDER GROUND USE IS BEING USED FOR UNDER GROUND CABLING FOR ELECTRICAL SERVICES, ELECTRICAL DISCONNECT BOX LOCATED AT GAS HOUSE IS HAZARDOUSLY ATTACHED TO ROOF, DOUBLE LUGGING FOUND AT 2ND ILLEGAL ELETRICAL DISCONNECT BOX WHICH WAS ADDED W/OUT PERMITS LOCATED ON ILLEGAL STRUCTURES. ELECTRICAL EXTENSION CORDS BEING USED AS PEMENENT WIRING FOR ELECTRICAL SERIVCE TO ILLEGAL STRUCTURES LOCATED AT BACK OF PROPERTY. ALSO FOUND A LARGE AMOUNT OF WASP NEST ON PROPERTY AGAIN. MEETING W/ADMIN AND SUPERVISOR: ADVISED TO HAVE 2 MAIN BLDGS BOARDED UP, WASP REMOVED TODAY. CONTACTED NORTHWEST EXTERMINATOR, BATHCREST, PD TO VERIFY BLDG VACANT BEFORE BOARDUP.