Case: T11DV06207

Parcel: 120071640


Addresses:

210 W PALMDALE ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/16/2011 INSP - INITIAL CODE ENFORCMENT Approved THE BEDROOM HAS BROKEN WINDOW PANES AND CAN NOT OPEN. COLD WATER VALVE HANDLE TO THE TUB IS INOPERABLE. FRONT DOOR DEAD BOLT IS INOPERABLE. THE FRONT DOOR HAS NO THRESHOLDS AND IS MISSING THE DOOR TRIM. THERE IS DRYWALL DAMAGE IN BATHROOM WALLS, HALLWAY AND IN THE KITCHEN WALL. THE FRONT DOOR AREA IS UNFINISHED. KITCHEN HAS AN ELECTRICAL OUTLET WITH A RECEPTACLE WHICH IS NOT PROPERLY SECURED. THE DRAIN-WASTE-VENT LOCATED ON THE EXTERIOR WALL DOES TERMINATES WITHIN TWO FEET OF THE KITCHEN WINDOW. THIS IMPROPER CONNECTION OF THE DRAIN WASTE VENT ALLOWS SEWAGE GAS IN THE IMMEDIATE AREA AND CAN ENTER THE BUILDING. THE GAS FIRED WATER HEATER EXHAUST GAS VENTILATION PIPE IN NOT INSTALL PROPERLY AND IS CURRENTLY VENTING ON THE SIDE THE HOME NEXT TO A KITCHEN WINDOW AND BELOW THE ROOF. THE GAS FIRED WATER HEATER DOES NOT HAVE A DISCHARGE PIPE. BOTH AIR VENTILATION REGISTERS ARE MISSING FROM THE LIVING AND BEDROOM. THE BEDROOM HAS BROKEN WINDOW PANES AND CAN NOT OPEN.