Case: T11DV05739

Parcel: 120077180


Addresses:

437 W PALMDALE ST

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
10/13/2011 INSP - FOLLOW UP CODE ENFORCE Approved POWER RESTORED PER PERMIT OCCUPANCY APPROVED
CLOSE CASE
08/24/2011 INSP - FOLLOW UP CODE ENFORCE Approved ON SITE INSPECTION RESULTS: OWNER EMILY DOUKHOWETSKY WAS HOME AND LIVING IN THE UNIT WITH AN EXTENSION CORD PLUGGED IN TO DWELLING FROM THE ADJACENT PROPERTY. THE DWELLING UNIT DOES NOT HAVE POWER. I INSPECTED THE SERVICE PANEL AND NOTICED THE ELECTRODE GROUNDING CONDUCTOR HAS BEEN CUT. THERE MULTI CONDUCTORS IN THE PANEL NOT CONNECTED OR PROPERLY SECURED. I ADVISED THE OWNER THAT SHE CAN NOT LIVE IN THE DWELLING UNIT DUE TO LACK OF POWER. INSPECTOR LOPEZ DID CONDEMN THE UNIT ON 7-19-2011. TEP HAD ALREADY CUT THE POWER OFF PRIOR TO INSPECTOR LOPEZ INSPECTION. THE OWNER SAID IT WAS DUE TO LACK OF PAYMENT. INSPECTOR LOPEZ'S PLACARD WAS REMOVED, I RE POSTED THE PLACARD WHICH READS UNFIT TO OCCUPY AND ADVISED THE OWNER NOT TO REMOVE IT. I ALSO ISSUED AN ORDER TO VACATE AND HAD HER SIGN IT, I ALSO ISSUED AN ORDER TO REMOVE THE EXTENSION CORD AT ONCE AND SHE DID. SHE STATED SHE WAS GOING TO HAVE A FRIEND PICK HER UP LATER. I TOOK PHOTOS AND TOLD HER I WOULD MONITOR THE PROPERTY FROM TIME TO TIME.

THE OWNER DOES HAVE AN ACTIVE RECONNECT PERMIT T11EL01534.
INSPECTION RESULTS BELOW .
IVRS - Inspection 6-03-2011
See detailed listing on site.| 999*
1) 50 AMP CIRCUIT IN PANEL TRIPLE LUGGED. 50 AMP CIRCUIT WITH 12-? WIRING. IMPROPER CONNECTIONS ADDED CIRCUIT TO PANEL
2) CIRCUIT TO REAR STORAGE PROTECT FROM PHYSICAL DAMAGE. HAZARDOUS ELECTRICAL INTERIOR NOT TO CODE
3) PANEL NOT GROUNDED
4) SMOKE ALARM BEDROOMS
5) HAZARDOUS ELECTRICAL REAR ROOM JUNCTION BOX OVER FILLED AND IMPROPER CONNECTIONS AT BOXES

IVRS - Inspection :*8-08-2011
1) COMPLY WITH PREVIOUS
2) NEXT DENIAL OR NOT READY MAY RESULT IN REFEE

SCHEDULE A 60 DAY FOLLOW UP INSPECTION