Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T11DV04943
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2011 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL OUT: HOUSE FIRE, DAMAGE TO THE REAR 8 X 14 WOOD FRAMED PORCH, ALL RAFTERS, ROOF SHEATHING ALONG WITH THE BEAM AND TWO POSTS HAVE ALL ALLIGATORING CRACKS AND ARE CHARRED. THE REAR WEST END OF THE MAIN HOMES EAVE AREA HAS THE SAME DAMAGE THE VENTS TO THE GABLE END ARE BENT. THE EXTERIOR FRAME OF THE 1X6 BATHROOM WINDOW HAS MELTED AND IS BROKEN. THE INTERIOR DAMAGE IS TO THE REAR SLIDER DOOR AMD 6 INSPECTION HOLES TO THE DRYWALL CEILING AREA ESTIMATE 100 SQ FEET. THE ELECTRICAL DAMAGE IS ONE EXTERIOR WALL RECEPTACLE AND A WALL LIGHT FIXTURE BOTH HAVE COMPLETELY MELTED. MILD SMOKE DAMAGE IN THE INTERIOR. TEP BOOTED METER OFF, SWG PINNED METER OFF. OK TO REOCCUPY ONCE ELECTRICAL IS REPAIRED UNDER A PERMIT. STRUCTURAL DAMAGE IS TO THE EXTERIOR. FIRE DID NOT PENETRATE THE INTERIOR OF THE DWELLING UNIT. THE DWELLING WAS CONDEMNED UNFIT TO OCCUPY FOR LACK OF POWER. PERMITS REQUIRED FOR REPAIRS. SCHEDULE A 60 DAY FOLLOW UP INSPECTION FOR AREA INSPECTOR. |