Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/06/2011 | INSP - INITIAL CODE ENFORCMENT | Approved | THE SOUTH EXTERIOR ADOBE WALLS FINISH HAS A 10 FOOT BY 10 FOOT STUCCO SECTION THAT HAS BUCKLED AND DETACH ITSELF FROM THE ABODE WALL, NO DAMAGE TO THE INTERIOR OF THE BUILDING. ONE BEDROOM HAS A WINDOW PANE BROKEN.TRASH AND DEBRIS, LITER ON THE PROPERTY.GRASS AND WEEDS EXCEED 6 INCHES IN HEIGHT ON THE PROPERTY.A 10 FOOT X 10 FOOT WOOD FRAMED STRUCTURE IS CURRENTLY ATTACHED THE DWELLING AND IS IN A DILAPIDATED STATE. THE STRUCTURE IS NOT CONSTRUCTED PER THE 2006 INTERNATIONAL BUILDING CODE. THE POSTS ARE 2X4 NON TREATED WOOD MEMBERS WHICH ARE EMBEDDED IN THE EARTH. THE STRUCTURE HAS A CROSS MEMBER BEARING ITS OWN WEIGHT AND HAS FAILED. THIS STRUCTURE IS UNSAFE AND IN A COLLAPSING STATE. |