Permit: T11CM03937

Parcel: 11612751A


Addresses:

550 N SILVERBELL RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
08/27/2012 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
07/24/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PROGRESS ON SITE WALL
07/19/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOPOUT CONDUCTOR & TOTE STORAGE
07/16/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT ON COMPACTOR & TOTE STORAGE
07/15/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PROGRESS AREA ON SITE WALL WEST & NORTH OK
07/12/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/11/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST SITE WALL 1ST LIFT SOUTH TO NORTH
07/02/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GL B-0 1 28' LIFT
06/29/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/27/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GL C-E/1 20' LIFT, E/1 -2.8 20' LIFT
06/26/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GL 1-3/E 18' LIFT
06/22/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
OKAY TO GROUT SOUTH WEST CORNER
06/18/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/15/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/14/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/13/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/11/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/08/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
8' LIFT GL 1.3-2.8/A
06/07/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/05/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
G2 1/A-C 3RD LIFT 1.8-2.5/ A 1ST LIFT
06/04/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 3RD LIFT EAST SIDE 40' SOUTH AND NORTH SIDE 3RD LIFT
06/01/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) GL: 1/A-C.2 2ND LIFT; A/1-1.2 2ND LIFT; D.5-E/1; 1.6/E
05/31/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) GL: 2.8-4/E 2ND LIFT; 4/A-E 2ND LIFT; 2.8-4/A 2ND LIFT; 1ST LIFT E/1; A/2.5-Z 1ST LIFT
05/29/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST WALL-NORTH 1/2-1ST LIFT
2) NORTH WALL-EAST 1/2- ST LIFT
3) EAST WALL-1S LIFT
4) SOUTH WALL-EAST 1/2-1ST LIFT
05/21/2012 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*