Permit: T11CM03895

Parcel: 10409002D

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T11CM03895

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/16/2012 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/11/2012 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
RESTROOM KITCHEN AND BAR AREA
07/03/2012 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
06/08/2012 PLUMBING - INTERMEDIATE Not ready for Inspection 1. Interceptor installed and tested OK. 2. Vent fittings below the flood rim to be drainage type. 3. Sewer air test OK. 4. All non-metallic bldg. utilities, drains, vents, etc. to have tracer. 5. Need to see bldg. drain to bldg. sewer connection.