Permit: T11CM03890

Parcel: 111081600


Addresses:

2445 N ALVERNON WY

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/06/2012 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
01/26/2012 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) PROVIDE TRACER WIRES FOR YARD WATER LINES
2) PROVIDE VACUUM BREAKERS AT HOSE BIBS
3) FILL IN AROUND TUB SHOES
4) UPSIDEDOWN SAN TEE IN UNITS 2453 & 2455
5) PROVIDE 2" STAND PIPE FOR WASHER DRAIN UNIT 2457
6) DO NOT USE MPT INTO FEMALE PLASTIC