Permit: T11CM03845

Parcel: 120052720


Addresses:

902 W IRVINGTON RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T11CM03845

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2012 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
02/17/2012 PLUMBING - ROUGH, SOIL Partial Approval 1) WATER LINE STUBBED DOWN WITH BACKFLOW OK
2) ABS AND PVC MAY NOT BE INTERMINGLED
3) TRANSITION CEMENT MAY ONLY BE USED WHERE THE BLDG DRAIN CONNECTS TO THE BLDG SEWER, MISSION BANDS WOULD BE THE CORRECT TRANSITION
4) BLAKE TEES ARE NOT LISTED TO BE USED AS A TEST FITTING BELOW GRADE, USE A DIRECTIONAL FITTING FOR TESTING. WILL ACCEPT PHOTO
5) OK TO BACKFILL
02/16/2012 PLUMBING - ROUGH, SOIL Cancelled CANCELLED PER CONTRACTOR ED #602-663-7379
02/16/2012 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) CALLED AND LEFT MSG., YOU ASKED FOR AN AM INSPECTION