Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T11CM03727
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/27/2012 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/23/2012 | PLUMBING - FINAL | Not ready for Inspection | 1. See P1 Plumbinng Fixture List: General Notes... 2. No grates or strainers. 3. PVC requires purple primer as well as solvent cement. 4. May not combine ABS and PVC solvent weld fittings. 5. Backflow device may not be installed above five feet. 6. Gas not installed per plan. Flexes undersized for appliances. 7. Corrugated tailpiece not permitted. 8. Method of sterilization. Clean bacteria report. 9. May not be a complete list. |