Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T11CM03727
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2012 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/27/2012 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) ABS IS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES, THRU NO MORE THAN 4' BETWEEN HANGERS 2) SUPPORT VERTICAL PIPE 3) ISOLATE ABS FROM METAL STUDS 4) TEST ALL PIPING THRU THE ROOF 5) JIM CAPS MAY NOT BE USED IN LIEU OF BLIND PLUGS 6) SUPPORT EXISTING CAST IRON AND COPPER AS REQUIRED BY TABLE 3-2 |