Inspection History Details
Inspection Status: Cancelled
Inspection History: PLUMBING - PRE SLAB
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/27/2012 | PLUMBING - PRE SLAB | Cancelled | CANCELLED PER CONTRACTOR KIM #602-323-7107 | |
| 02/27/2012 | PLUMBING - PRE SLAB | Approved | IVRS - Inspection :* 1) ABS DWV UNDERSLAB OK TO COVER 2) WRAP PIPE THRU SLAB 3) USE APPROVED STRAPS 4) ISOLATE PLASTIC FROM METAL STUDS |
|
| 02/17/2012 | PLUMBING - PRE SLAB | Not ready for Inspection | 1) RECTOR SEAL NUMBER 5 IS NOT PERMITTED WITH ABS 2) A BLAKE TEE IS LISTED AS A VERTICAL SURFACE WALL CLEANOUT. IT IS NOT A DRAINAGE FITTING AND MAY NOT BE USED BELOW GRADE, OR ON IT'S BACK. USE DIRECTIONAL FITTING 3) WRAP PIPING THRU SLAB 4) PLAN CALLS FOR TYPE "K" COPPER BELOW GRADE 5) INSULATE WATER PIPING PER PLAN |