Permit: T11CM03727

Parcel: 10503033A

Inspection Status: Cancelled

Inspection History: PLUMBING - PRE SLAB

Permit Number - T11CM03727

Inspection Description - PLUMBING - PRE SLAB

Inspection Status - Cancelled

Date Description Inspector Results Comments
02/27/2012 PLUMBING - PRE SLAB Cancelled CANCELLED PER CONTRACTOR KIM #602-323-7107
02/27/2012 PLUMBING - PRE SLAB Approved IVRS - Inspection :*
1) ABS DWV UNDERSLAB OK TO COVER
2) WRAP PIPE THRU SLAB
3) USE APPROVED STRAPS
4) ISOLATE PLASTIC FROM METAL STUDS
02/17/2012 PLUMBING - PRE SLAB Not ready for Inspection 1) RECTOR SEAL NUMBER 5 IS NOT PERMITTED WITH ABS
2) A BLAKE TEE IS LISTED AS A VERTICAL SURFACE WALL CLEANOUT. IT IS NOT A DRAINAGE FITTING AND MAY NOT BE USED BELOW GRADE, OR ON IT'S BACK. USE DIRECTIONAL FITTING
3) WRAP PIPING THRU SLAB
4) PLAN CALLS FOR TYPE "K" COPPER BELOW GRADE
5) INSULATE WATER PIPING PER PLAN