Permit: T11CM03727

Parcel: 10503033A

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T11CM03727

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/23/2012 FRAMING Approved IVRS - Inspection :*
03/15/2012 FRAMING Partial Approval IVRS - Inspection :*
1) SCREWS TO JOIST NOT PER PLANS
2) NEED DETAILS FOR HANGING SOFFITS
3) MISSING KICKERS
4) WALLS ONLY