Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T11CM03707
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/19/2013 | PLUMBING - PROGRESS | Approved | PER PLUMB FINAL | |
02/22/2013 | PLUMBING - PROGRESS | Partial Approval | CLOSET GLANGES OK TO SET ALL TOILETS | |
02/21/2013 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1ST LEVEL CLOSET FLANGES, CORRECTIONS OK. | |
02/12/2013 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
02/05/2013 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :*CLOSET FLANGES 2ND LEVEL AND 4TH LEVEL WEST HALF | |
02/01/2013 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
01/31/2013 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :*LEVEL 4 ABV CEILING OK LEVEL 4 NORTH AND WEST CORRIDOR CLOSET FLANGES OK |
|
01/24/2013 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
01/17/2013 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* use proper tools to set closet flanges |
|
12/18/2012 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* LEVEL 1 AREA C, CAFE INSTALLED PER UNAPPROVED P-401 AND P211 NOTE #3, WITH TEST OK, SUBJECT TO CITY REVIEWED AND APPROVED PLAN. NOTE; WASH AND RINSE COMPARTMENTS OF 3 COUP SINK REQUIRE A DIRECT CONNECTION. PROVIDE INSPECTOR WITH CITY APPROVED PLANS AS SOON AS YOU GET THEM. YOU HAVE SOME OUTSTANDING ITEMS WAITING ON PLAN REVIEW: SEE INSPECTION HISTORY (3 PERMITS) L4 DOMESTIC WATER W/ 100PSI TEST OK WAITING ON REVISION FOR MATERIAL TYPE. L4 SHOWER PAN LINERS W/ TEST OK. CALL FOR CLOSET FLANGE INSPECTIONS. NEED LABELS ABOVE CEILING COMPLETE PIPE INSULATION |
|
12/07/2012 | PLUMBING - PROGRESS | Partial Approval | 2ND LEVEL SHOWEROK | |
10/03/2012 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
09/24/2012 | PLUMBING - PROGRESS | Not ready for Inspection | PLASTIC PIPING SHALL BE TESTED WITH POTABLE WATE NOT AIR AS PRESCRIBED BY 2006 UPC 609.4 | |
08/20/2012 | PLUMBING - PROGRESS | Not ready for Inspection | PLUMBING NOTE#9 INSTALL CLEAN OUTS AT ALL SINKS. | |
07/26/2012 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
06/18/2012 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* POLYPROPYLENE DOMESTIC WATER REQUIRES APPROVAL FROM COT BUILDING OFFICIAL NOTE ALL PIPING SHALL BE DEBURRED NO PIPING MAY BE COVERED PRIOR TO TESTING |
|
05/23/2012 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) JOE HALL PLUMBING FOREMAN 631-1268 AND CHRIS W/ JE DUNN 400-3915 |