Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
Permit Number - T11CM03707
Inspection Description - SHEET ROCK NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/22/2013 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
03/11/2013 | SHEET ROCK NAILING | Partial Approval | E.C ENTRY AREA OK TO TAPE PROGRESS AREA | |
01/30/2013 | SHEET ROCK NAILING | Partial Approval | 3RD LEVEL ELEVATOR/RECEPTION AREA,2ND LEVEL ELEVATOR SOFEFIT OK TO TAPE PROGRESS AREAS | |
01/16/2013 | SHEET ROCK NAILING | Partial Approval | ext walls of elec rm #16013 elevator area of 1st floor area; 2nd floor elevator/reception area-ok to tape progress area | |
01/11/2013 | SHEET ROCK NAILING | Partial Approval | #7 first floor restrooms 16009,16010 | |
01/09/2013 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* EAST RECEPTION AREA WALLS AND CEILINGS OK TO TAPE PROGRESS AREAS | |
01/07/2013 | SHEET ROCK NAILING | Partial Approval | 3RD LEVEL CORRIDOR 30274: OR #5 20429, 20446, 20488 OK TO TAPE PROGRESS AREAS | |
12/24/2012 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* CORRIDOR #20445 CEILING OF TO TAPE. | |
12/19/2012 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :*1ST LEVEL WAITING AREA SOFFITS OK TO TAPE | |
12/12/2012 | SHEET ROCK NAILING | Partial Approval | 2ND LEVEL RECEPTION AREA; LEAD SHIELDING IN ROOMS # 16199, 2ND LEVEL OR'S #5,7 | |
11/19/2012 | SHEET ROCK NAILING | Partial Approval | 3RD LEVEL OK #9 SHELL SPACE # 30272 30272- OK TO POUR PROGRESS | |
11/15/2012 | SHEET ROCK NAILING | Partial Approval | operating rooms 3rd level #4,6,7,8 | |
11/14/2012 | SHEET ROCK NAILING | Not ready for Inspection | IVRS - Inspection :* | |
11/08/2012 | SHEET ROCK NAILING | Partial Approval | LEVEL 4 AREA "A(EAST)- ALL AREAS OK TO TAPE PROGRESS AREAS | |
11/05/2012 | SHEET ROCK NAILING | Partial Approval | LEVEL#2 OR CEILINGS- EXCEPT #'S 5 AND 7 OK TO TAPE PROGRESS AREAS | |
10/30/2012 | SHEET ROCK NAILING | Partial Approval | EXISTING BLDG- 2 EXAMS ROOMS AND ENTRY WAY | |
10/29/2012 | SHEET ROCK NAILING | Partial Approval | LEVEL 4 NORTHWEST AND SOUTHWEST QUADRANTS | |
10/22/2012 | SHEET ROCK NAILING | Partial Approval | 2ND LEVEL AREA B ALL OR'S EXCEPT #'S 2,5,7 CORRIDORS 20475, 20445,20450 |
|
10/15/2012 | SHEET ROCK NAILING | Partial Approval | level #5 bottle room; level #2-4 ok's level #4 shaft areas level #1 area e ok to tape progress areas |
|
10/02/2012 | SHEET ROCK NAILING | Partial Approval | LEVEL 1 AREA"B" GL:7/C-K.5; C/4.5-7; AREA"A" CORRIDORS 0463, 0403, 10435 OK TO TAPE PROGRESS AREAS. | |
09/27/2012 | SHEET ROCK NAILING | Partial Approval | 3RD LEVELL-AREA A: GL 1/A-D; A/1-4.5 4.5/A-D | |
09/25/2012 | SHEET ROCK NAILING | Partial Approval | 2ND LEVEL SOUND BOARD IN PATICUT ROOMS #20369_20383 OK TO TAPE [PROGRESS AREAS | |
09/17/2012 | SHEET ROCK NAILING | Not ready for Inspection | IVRS - Inspection :* | |
09/10/2012 | SHEET ROCK NAILING | Partial Approval | LEVEL #2- AREA C: ROOM # 20531, 20532, 20536, 20533, 20537, 20538, 20534, 20316, AREA A: PACU#1-6 (PED) RR #1-21 (WALLS ONLY) RESTROOMS 20348, 20365,: CORRIDOR 20463 | |
09/04/2012 | SHEET ROCK NAILING | Partial Approval | 2ND LEVEL CORRIDORS EXCEPT CORRIDOR # 20475 CORRIDOR #20445(NORTH WALL)= NEW SE STATION SOFFITS-OK TO TAPE PROGRESS AREA. | |
07/31/2012 | SHEET ROCK NAILING | Partial Approval | 2ND LAYER AT EXISTING #1 OK TO TAPE | |
07/26/2012 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection : EXTERIOR SHEATHING FOR WIRING WALL GL C/0.3 -1- OK TO COVER PROGRESS AREA |
|
06/14/2012 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* | |
05/17/2012 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* DROP DOWNS AT 4' 10" BELOW DECK; CORRIDOR AND ROOMS-GL: 3.5/E-K; 2.5/E-K OK TO TAPE PROGRESS AREAS |