Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM03616

Parcel: 137277920


Addresses:

1607 W MAPLEWOOD DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/17/2012 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/10/2012 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BRACED PANEL NAILING 6' ON CENTER ALL EDGES 12" IN FIELD
2) MISSING DBL TOP PLATES BEARING WALLS. INSTALL PLATES OR STUD UNDER TRUSSES WITHIN 1 1/2"
3) X BRACE GABLE END
4) PROVIDE 2-2 X 8 BOX HEADERS PER PLAN
5) PROVIDE 2 ABS PER BRACED PANEL
6) PROVIDE SAFE ACCESS TO ROOF