Permit: T11CM03572

Parcel: 134172630


Addresses:

7110 E 17TH PL

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
11/28/2011 BUILDING - PROGRESS Approved IVRS - Inspection :*
11/23/2011 BUILDING - PROGRESS Denied GFI OUTLET NOT GROUNDED - WILL NOT TRIP
11/22/2011 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXPOSE FOOTINGS (POST OR CONTINOUS)
2) NAIL OFF EXTERIOR SIDING
3) NAIL OFF HOLDOWNS PROPERLY TO CODE
4) ANCHOR BOLTS NEEDED AT SILL PLATES TO CODE
5) VERIFY SELF CLOSING HINGES FROM HOUSE TO GARAGE
6) GFI PROTECT OUTLET IN GARAGE