Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/28/2011 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
12/07/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) ALL DWV PIPING ABOVE GRADE TO BE N/H 2) DBL SANTEE NOT APPROVED FOR FLOOR DRAINS 3) PLAN CALLS FOR SOILD CORE PVC |
|
12/07/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) VERTICAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 2) REQUIRE 6" BETWEEN TRAP WEIR AND POINT OF VENT OK 3) OK TO COVER EVERYTHING AFTER WRAP |