Permit: T11CM03524

Parcel: 105110700

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/28/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
12/07/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) ALL DWV PIPING ABOVE GRADE TO BE N/H
2) DBL SANTEE NOT APPROVED FOR FLOOR DRAINS
3) PLAN CALLS FOR SOILD CORE PVC
12/07/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) VERTICAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP
2) REQUIRE 6" BETWEEN TRAP WEIR AND POINT OF VENT OK
3) OK TO COVER EVERYTHING AFTER WRAP