Permit: T11CM03477

Parcel: 126131980


Addresses:

4601 E MALVERN ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T11CM03477

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/19/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
12/07/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A TRAP IN CONDENSATE DRAIN LINE AND AN OVERFLOW SENSOR ON SECONDARY DRAIN OUTLET
2) INSTALL A HOSE CLAMP ON PLASTIC HOSE CONNECTION TO PUMP
3) DO NOT USE FLEX COPPER ON THE T & P DRAIN LINE ON WATER HEATER
4) MUST BE SMOOTH INTERIOR WITH 3/4" I.D.
5) THE CONDENSOR STAND MUST HAVE STEEPERS THAT SPAN AT LEAST 3 ROOF JOISTS
6) USE REDWOOD OR PRESSURE TREATED WOOD AND SECURE THE STAND TO THE SLEEPERS
11/30/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE ACCESS TO FURNACE, WATER HEATER, ROOF TOP A/C UNIT
NOTE: I DID NOT SEE A FURNACE OR WATER HEATER VENT ON ROOF. IF THEY ARE TERMINATED INTO A T-TOP WIT ABESTOS OR TRANSITE VENT PIPING, THEY WILL NEED TO BE REPLACED WITH APPROVED DBL WALL PIPE WITH APPROVED CAPS