Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2011 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/07/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NO PORTION OF ANY WORK MAYBE CONCEALED BEFORE IT HAS BEEN INSPECTED AND APPROVED 2) ISOLATE PVC FROM METAL STUDS AND SUPPORT HORIZONTAL PVC 3) FINISH INSULATION PER MANUFACTURERS SECS, I.E....LAGGING ADHESIVE AND 10 MIL TAPE 4) SUPPORT ALL OVERHEAD PIPING PER TABLE 302 2006 UPC |