Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM03433

Parcel: 136132990

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Date Description Inspector Results Comments
01/12/2012 SHEET ROCK NAILING Approved IVRS - Inspection :*
01/11/2012 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING BLOCKED NAILING IN MASTER CLOSET
2) 6" ON CENTER NAILING WITH 1 7/8" NAILS OR EQUIVALENT SCREWS NEEDED IN GARAGE CEILING WITH HABITAL ABOVE
12/21/2011 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1) PARAPET OK
12/13/2011 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1) BELLY BAND FIRE ROCK OK