Permit: T11CM03433

Parcel: 136132990

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/12/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/09/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 1/2" A.B.'S NEEDED FOR #6 SHEARWALL BACKWALL
2) NAILS FOR BELLY BAND TO BE IN BOTTOM PLATE OF 2ND FLOOR WALL PER 3/S6.1 AND 1/S6.1
3) INSPECTION NEEDED ON 1 HR FIREWALL AT RIM
4) REVISION FOR HEADER SIZE FOR POCKET DOOR IN KITCHEN
5) OSB NAILING AT FLOOR TRUSS ABOVE SHEAR PANELS TO MATCH BELOW PER 3/S6.2
6) BLOCKING NEEDED TO MEET NAILING OF THA418 HANGERS AT FOYER
7) STOPPED INSPECTION TO MANY ITEMS TO LIST