Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM03315

Parcel: 140201390

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/13/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/08/2011 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) MISSING CMST14 STRAPS INTO DBL STUD AT BEDROOM 2 TO LIVING ROOM 1ST TO 2ND FLOOR