Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/27/2011 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM 1 DATED 10/25/11 HAS NOT BEEN DONE, A REINSPECTION FEE IS BEING ATTACHED TO THIS PERMIT, COMPLETE ALL WORK NOTED BY INSPECTOR PRIOR TO CALLING FOR REINSPECTION |
|
| 10/25/2011 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) SINGLE WALL VENT ON WATER HEATER MUST HAVE 6" CLEARANCES FROM COMBUSTIBLE PIPE INSULATION 2) WATER HEATER VENT CANNOT TERMINATE INTO A T-TOP 3) TERMINATE ABOVE THE ROOF WITH APPROVED CAP 4) RESCHEDULE FOR PLUMBING FINAL |