Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T11CM03148

Parcel: 141350520

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T11CM03148

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/09/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/08/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BELLY BAND NAILED TO BOTTOM PLAT OF SECOND FLOOR OR STRAP TO PLAN
2) H3'S MISSING AT PATIO LEDGER PER PLAN 308-SD
3) 16D NAILS NEEDED AT HOLDOWNS
4) A34 & A35'S NEEDED AT STAIRWAY
5) LAG BOLT EXTERIOR PLATES WITHIN 12" OF PLATE SEAMS
6) NAIL OFF SEAMS TO BIRD BOARDS