Permit: T11CM03090

Parcel: 13220003A


Addresses:

3401 E GAS RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T11CM03090

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/23/2012 PLUMBING - INTERMEDIATE Approved
08/28/2012 PLUMBING - INTERMEDIATE Partial Approval PLMG PRE SLAB AT MECH-ROOM OK
08/27/2012 PLUMBING - INTERMEDIATE Not ready for Inspection DWV HEAD TEST FAILED
08/10/2012 PLUMBING - INTERMEDIATE Partial Approval PHASE ONE COMPLETE. OK TO OCCUPY GANG BATHROOMS
WILL REOPEN REQUIRED INSPECTIONS FOR PHASE TWO.
06/13/2012 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
06/13/2012 PLUMBING - INTERMEDIATE Partial Approval 1. Horizontal cleanout extensions at lavatories should be combos. Since the horizontal distance is minimum, no correction required at this time. OK to cover walls.
06/11/2012 PLUMBING - INTERMEDIATE Partial Approval 1. All of the DWV system to be subjected to a test to ten feet. So that no joint or pipe shall have been tested with less than a ten foot head. 2. Cleanouts are to extend to the surface of the wall through a wye branch fitting. 3. OK to insulate hot and return piping.