Permit: T11CM03057

Parcel: 13819029C

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T11CM03057

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/24/2011 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
10/18/2011 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) CONDENSATE NOT PROPERLY INSTALLED, PROVIDE PURPLE PRIMER AT ALL JOINTS, MOVE VENT OUTSIDE OF RETURN AIR CABINET, ALL FITTINGS ARE TO BE STRAIGHT AND TRUE, DO NOT STRESS FITTINGS
2) LINE SETS NOT PROPERLY INSULATED, USE PROPER INSULATION, INSTALL FULL LENGTH PER INSTALLATION INSTRUCTIONS