Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T11CM03041
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/17/2013 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 04/15/2013 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 04/15/2013 | PLUMBING - FINAL | Not ready for Inspection | BACK FLOW PROTECTION AT HYRID UNIT NOT EQUIRED PER ROBERT BOWLIN PO: HAS AIR CAP INSTALL BACK FLOW SHOWN FOR ICE MAKER SEPARATE CONDENSATE FROM BIN DRAINS. PROVIDE AN AIR GAP AT DRAIN TERMINATIONS. INSTALL A FUNNEL ATTACHMENT TO INDIRECT RECEPTOR. RO EQUIPMENT REQUIRES AN AIR GAP, ALSO PROPER USE OF FITTINGS. CPUC NOT COMPATIBLE W/ PVC. HOSE BIB AT HYBRID UNIT REQ VAC BREAKER AND FREEZE PROTECTION. TRAP SEAL PROTECTION FOR DRAINS W/OUT CONT USE EXTEND VTR AT ROOF HATCH. PROTECT ALL EXPOSED PLASTIC. COMPLETE OVERHEAD PIPE SUPPORTS. GAS REGULATOR VENTS SHALL TERMINATE MIN OF 3' FROM SPARK. SEALL ALL CLEAN OUT PLUGS - PLUGS SHALL BE TESTED TO RECOVER SCREW |
|
| 04/09/2013 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 04/09/2013 | PLUMBING - FINAL | Partial Approval | COMBI OVENTS ARE MISSING BACKFLOW PROTECTION. COMPLETE ALL WORK SHOWN ON PLANS, AND ANY OUTSTANDING ISSUES. | |
| 04/04/2013 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*SHOW HOW HYBRID HOUSE AND EVAP CONDENSER DONESTIC WATER SUPPLY IS PROTECTED FROM BACKFLOW AS REQUIRED PER CODE. CALL FOR AND HAVE APPROVED ALL OUTSTANDING REQUIRED INSPECTIONS. | |
| 03/26/2013 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* |