Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T11CM03041
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2013 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/04/2013 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/21/2013 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/05/2013 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*CORRECTION AT FREEZER PRE SLAB OK TO COVER | |
| 02/27/2013 | PLUMBING - INTERMEDIATE | Partial Approval | piping insulation in walls ok bakery, product and meat freezer dwv and test ok. still need to see pre slab corrections noted on 1.24 for piping at freezer location | |
| 02/26/2013 | PLUMBING - INTERMEDIATE | Not ready for Inspection | GAS TEST OK COPPER IN WALLS WITH TEST OK TO INSULATE PROVIDE A TEST ON CPVC AND DWV CORRECT VENTING AT 4" FD MAY NOT REVENT BELOW FLOOD LEVEL | |
| 02/21/2013 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*DELI AREA DWV W/ TEST THUR ROOF OK DOMESTIC WATER IN WALLS W/ INSULATION OK | |
| 02/20/2013 | PLUMBING - INTERMEDIATE | Partial Approval | WATER OM WALLS ALL JOINTS REQ A TEST. WHEN TESTING IN SECTIONS, THE UPPER PART OF THE PREVIOUSLY TESTED SECTION SHALL BE RETESTED SO NO JOINTS GO UNTESTED. O TO INSULATE WATER IN WALLS |
|
| 02/05/2013 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*PHARMACY AND TOILET RMS; DWV W/ TEST OK. WATER OK TO INSULATE, PROVIDE TEST | |
| 02/04/2013 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |