Permit: T11CM02975

Parcel: 106020650


Addresses:

200 E ROGER RD 01

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/25/2012 PLUMBING - FINAL Approved IVRS - Inspection :*
05/22/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ONLY ONE SLIP NUT ALLOWED ON THE OUTLET SIDE OF THE TRAP
2) FINISH INSULATION AT WATER HEATER
3) SUPPORT RECIRC. PUMP
4) REQUIRE 15" FROM CENTER LINE TO SIDE WALL OR OBSTRUCTION ON WATER CLOSET. 18" CENTER TO SIDEWALL OR OBSTRUCTION FOR HANDI CAPPED
5) REMOVE COVERS ON EWC
6) CLEANOUT EXTERIOR FLOOR SINKS AND INSTALL STRAINERS
7) URINAL TO BE 17" AFF TO OVERFLOW MAX
8) METHOD OF STERILIZATION
9) CLEAN BACTERIA REPORT AND BACKFLOW CERT