Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/10/2011 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/08/2011 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MOVE SMOKE DETECTORS 3' AWAY FROM DUCT VENTS 2) PROVIDE A COMPLETE WATER TEST ON ALL DWV 3) MOVE DUCT OFF METAL GUSSET PLATES 4) PROVIDE ENGINEERED FIX FOR DAMAGED TRUSSES BY DUCT WORK (GUSSET PLATES) 5) NOT A COMPLETE LIST-BUILD TO APPROVED PLANS |