Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/09/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/30/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/29/2011 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE APPROVED SINGLE WALL VENT CONNECTOR FOR GAS WATER HEATER (LISTED CONNECTOR IS ALTERED) 2) COMPLETE RELIEF DRAIN PIPING GRAVITY DRAIN TO DAYLIGHT 3) PROVIDE PROTECTION BARRIER FROM AUTO IMPACT AND TANK 4) SEAL SOLAR LOOP PIPE THRU FLASHING 5) UPPER FLASHING TO BE INSTALLED WITH CORRECT UNDER LAP OF UPPER TILE 6) SECURE SOLAR LOOP TUBING IN ATTIC AT CORRECT INTERVALS 7) FIRE STOP GARAGE PIPE PENETRATIONS THRU GARAGE CEILING |
|
| 09/28/2011 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled |