Permit: T11CM02898

Parcel: 12510003F


Addresses:

3435 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Permit Number - T11CM02898

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
07/22/2013 PLUMBING - PROGRESS Approved IVRS - Inspection :*
07/10/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
07/10/2013 PLUMBING - PROGRESS Not ready for Inspection SEAL JOINTS OF PIPE INSULATION
REPLACE OR INSTALL ANY MISSING SUPPORTS
06/27/2013 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
06/27/2013 PLUMBING - PROGRESS Partial Approval PVC CONDENSATE LINES FOR COOLERS; SECURED ELEVATED
06/04/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
06/04/2013 PLUMBING - PROGRESS Not ready for Inspection PVC FOR THREADED FITTINGS ARE NOT TO BE CONCEALED; TRIM OUT ALL CLEAN-OUT FITTINGS IN WALLS. SEAL ALL PIPE INSULLATION.
05/02/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
05/02/2013 PLUMBING - PROGRESS Not ready for Inspection PROVIDE BACKFLOW PROTECTION FOR ROOF TOP EQUIPMENT AS REQUIRED BY UPC 603 AND 301. IF UNITS HAVE INTERNAL PROTECTION, PROVIDE THE LISTING. REF GP5 #1 AND GP6. PROVIDE TRAP SEAL PROTECTION FOR ALL FLOOR DRAINS SUBJECT TO INFREQUENT USE PER UPC 1007 AND COT AMENDMENTS. ( HOSE BIB IN TR).
CITY OF TUCSON AND SW GAS REQUIRE 3' FROM GAS REGULATOR TO SPARK PRODUCING APPLIANCE, REF DETAIL. OR PROVIDE MANUFACTURES REQUIREMENTS. PROVIDE ACCESS TO ALL BACKFLOW ASSEMBLIES AS REQ PER UPC 603.3.4. DETAIL GP4 #3 SPECIFIES 72" TO SUB CRITICAL LEVEL. CODE REQUIRES MAX 60" ABOVE PERMANENT PLATFORM.
03/26/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
02/15/2013 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*SD AND RYAN W/ ROCHE.