Permit: T11CM02898

Parcel: 12510003F


Addresses:

3435 E BROADWAY BL

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
05/20/2013 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
05/20/2013 REINFORCED MASONRY PRE-GROUT Approved NE WALL (IN-FILL) TOPPED-OUT; SW PLANTER - OK TO GROUT PROGRESS AREAS
05/16/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/16/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL IN-FILL: GL: 3/G-G.5
05/15/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/15/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IN-FILL AREA GL: 3/G-G.5 AT 48" AFFE - OK TO GROUT PROGRESS AREAS
04/10/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/10/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 3 PLANTERS TOPPED OUT 24" A.F.F.E. GL: C.1/1-3 OK TO GROUT
04/04/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*3 PLANTERS AT 40" GL:C-C.7/10
04/02/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*CMU WALL AT 10': GL: 0.5-1.75/C.7
03/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* CMU WALLS AT 10' GL: F.4-F.5/0.3-0.5 TOPPED OUT: GL: AT 5'4" C.9/ 0.5-1; C.7/O.35-2 @ 9'4" OK TO GROUT PROGRESS AREAS
03/27/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/25/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LOADING DOCK CMU WALLS AT 10' GL:E.4/.05-.01
03/21/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/20/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* CMU WALL AT 32'8" GL: G.4-H/ 5.7-4.5; CMU WALL AT 30'8" GL: H/4.5-3 CMU WALLS AT 28'8" GL: 3-1/ E.4-H-ALL CMU WALLS ARE TOPPED-OUT
03/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* CMU WALLS AT 28'8" GL: 1/E.4-F7; H/8-9.5; CMU WALL GL: 3/H-F.; CMU WALLS AT 30'8" GL H/7-8; 7/G.4-H- OK TO GROUT PROGRESS AREAS
03/18/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*CMU WALLS AT 28'-GL: H/7-9; (TOP-OUT) AT 16'8": 3/G-H; AT 20'8" F.7-C.7/1-3 OK TO GROUT PROGRESS AREAS
03/14/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
cmu walls at 24'8":gl: g-4-h/9-6.5 cmu walls at 20'8";GL 1-2/ C.7-G-4: OK TO GROUT
03/13/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS AT 16'8" GL: C.7-D/1-2 CMU WALL AT 16'8" GL: 1/D-D.4; CMU WALLS AT 20'8" GL: 1-5.5/G-H;OK TO GROUT PROGRESS AREAS
03/12/2013 REINFORCED MASONRY PRE-GROUT Partial Approval * 2/c.7-c.9 SMU WALLS AT 16'8" gl: 1/D.2-E.7; CMU WALLS AT 20'8" GL: H/7-9 7/H-G.4- OK TO GROUT PROGRESS AREAS
03/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval *3/F.7-G; CMU WALL AT 12'8" GL:
1.2/D.2 E.4; CMU WALL AT 8'8" GL: E.9/.05-1 OK TO GROUT PROGRESS AREAS
03/09/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 12'8" GL: 1-3/F.7-H
E.8-E.4/0.75-1;CMU WALL AT 8'8" GL:1/ F.4-F.7
OK TO GROUT PROGRESS AREAS
03/07/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* CMU WALLS AT 8'8"-12'8", GL; H-G.4/4.5-10; CMU WALL AT 4'8" GL: C.9/1-2; CMU WALL AT 4'8"-8'8" GL: 1/D.W-E.4 OK TO GROUT PROGRESS AREAS
03/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* CMU WALLS AT 8'8" GL: H-G.4/1--3; 1-3/G-OK TO GROUT PROGRESS AREAS
03/05/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* RWL BELOW GRADE ALONG NORTH WALL. CMU WALLS AT 4'8" @GL: H-G-4/7-3; 1-3/H-G.2; A/E.7-F.7 1-2/D-C.7; OK TO GROUT PROGRESS AREAS
03/04/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*CMU WALLS AT 28'8"(TOP-OUT) -GROUTED- SPECIAL INSPECTED GL: 3.7-5.8/ C-C.7; AT 30'2" GL: C/8.4-8.6; AT 28'8"-C/8.6-9.4 CMU WALLS AT 27'4" GL: C.7/9.4-10; 10/C.Y-D.5; 10/F.5-H; H/8.5-10; AT 28'8" GL: 10/D.5-F.5 OK TO GROUT PROGRESS AREAS
03/01/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* CMU WALLS AT 24;8: GL: C.7-C/2-5 C/8.4-9.4; A0/C.Y-H-OK TO GROUT PROGRESS AREAS
02/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval cmu walls at 20'8" c-c.9/1-5.8
02/27/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/26/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 12'8"-16'8" GL: 3.8/B-C.1; B/3.8-5.8: 5.25-A.1-B;A.1/5.25-5.8;10/G.4.H H/9.5-10; CMU WALLS AT 20'8" GL: 9.4/C-C.7; C.7/9.25-10: OK TO GROUT PROGRESS AREAS
02/25/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 12'8" -16-8" GL: C.7\2-3.7
3.7/C.1-C.7 ; C.1/3.7-3.8; 3.8/ 3.8/B-C; B/3.7-4.25; 10/C.7-F.5 OK TO GROUT PROGRESS AREAS
02/22/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/21/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* CMU WALLS AT 8'8"-12'8" GL: 5-2/B-A.2 A.1/5.2-6.3; 8.4/C-C.7; 10/C.7-D.5; CMU WALL AT 8'8" GL: H/8.5-10 OK TO GROUT PROGRESS AREAS. STEM WALLS: GL: F.7/1-3; 1/F.7-F; F.7-F.4/ 0.05-1- OK TO GROUT PROGRESS AREAS
02/20/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CONTRACTOR CANCELLEED SHOWED OUT
02/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/14/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 8'8" GL: B/3.7-5;A.2/ 5-5.75; 9.4/C-C.7; 10/C.7-F CMU WALL 4'4"-GL H/7-8 OK TO GROUT
02/13/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/12/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*CMU WALLS AT 4'AFFE; GL: 3.7/C.7-C.1 C.1/3.1-3.2; 3.8/C.1-B; B/3.8-5.8; 5.1/ B-A.1; A.1/5.1-5.8; A.1/6.7-8.4; 8.4/A.2-C; 9.5/C.7-C OK TO GROUT PROGRESS AREAS
02/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*STEM WALLS AT 8"-48"; GL: C.7/2-3.75; 3.7/B-C.7; B/3.8-6 A.2-C.7/8-10; 10/C.7-11 H-G.4/3-10; 3/G-H- OK TO GROUT PROGRESS AREA