Permit: T11CM02819

Parcel: 141340680


Addresses:

5150 S EMMA CT


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T11CM02819

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/09/2012 BUILDING - FINAL Approved IVRS - Inspection :*
05/03/2012 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CAP OFF KNOCK OUT AT PANEL
2) ELECTRIC PANEL MIS-LABELED
3) DRIP T (SEDIMENT TRAP) NEEDED FOR WATER HEATER
4) SEAL TOILETS AT FLOOR
5) PROVIDE PLUG LISTED TO RECIEVE SCREW AT CLEANOUTS
6) PROTECT ARMAFLEX FOR A/C LINE SET