Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T11CM02718
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/27/2012 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/22/2012 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 5/S5.2 MISSING AT FRONT GABLE 2) STRAP BEAM TO TRIMMERS PER 6/S5.1 AT FRONT DOOR 3) COMPLETE 5/S5.2 PER PLAN AT PATIO GABLE (A34 AND NAIL DIAGONAL BRACE TO BLOCK BETWEEN TOP CHORDS) 4) NAILING OF SHEATHING MISSING ON BOTH SIDES OF ROOF 5) NAIL OFF DETAIL 5/S5.2 AFTER INSTALLING ON ROOF |